Models | ARM55D | ARM55W ARM55T (with switch) | ARM55C |
Usage | Mechanical Relay DryContact Output (“a”contact (NO)) (Single / Dual-redundant) | Mechanical Relay WetContact Output (Single /Dual-redundant) AUTO/OFF/ON switch (onlyfor ARM55T) | Mechanical Relay Dry Contack Output (“a” contact or “b” contact (NO or NC)) (Single / Dual-redun or dant)(*6) |
Contact Points | 32-point | 32-point | 32-point |
Terminals for Field Device Connection | M4 screws | M4 screws | M3.5 screws (*5) (M4 in power input part) |
Modules | ADV551 (DO: 32-point) + ATD5A (Terminal block)ADV561 (DO: 64-point)(*1) | ADV551 (DO: 32-point) + ATD5A (Terminal block)ADV561 (DO: 64-point)(*1) | ADV551 (DO: 32-point) + ATD5A (Terminal block)ADV561 (DO: 64-point)(*1) |
Signal Cables | AKB331 (for 32-point)AKB337 (for 64-point) | AKB331 (for 32-point)AKB337 (for 64-point) | AKB331 (for 32-point)AKB337 (for 64-point) |
Maximum Load (*2) | 250 V AC: 2 A per point 30 V DC: 2 A per point 125 V DC: 0.1 A per point (*3) | 250 V AC: 0.6 A per point 30 V DC: 0.6 A per point 125 V DC: 0.1 A per point (*3) | 30 V DC: 1.5 A per point |
Minimum Load | 5 V, 10 mA | 5 V, 10 mA | 5 V, 10 mA |
Power Supply Voltage and Current Consumption of Internal Circuit (requireexternal power supply) | 24 V DC Max.0.65 A | 24 V DC Max.0.65 A | 24 V DC Max.0.85 A |
Power Supply for Field Device (require external powersupply) | - | Dual-line (supply power per 16-point) 250 V AC: Max. 9.6 A 30 V DC: Max. 9.6 A 125 V DC: Max. 1.6 A | - |
Insulation Resistance | At least 10 MΩ (500 V DC) | At least 10 MΩ (500 V DC) | At least 10 MΩ (500 V DC) |
Withstanding Voltage | Between ?eld device terminalsand cases: 2 kV Between 24 V power terminals and cases: 500 V Between 24 V power terminals and ?eld device terminals: 2 kV | Between ?eld device terminalsand cases: 2 kV Between 24 V power terminals and cases: 500 V Between 24 V power terminals and ?eld device terminals: 2 kV | Between ?eld device terminalsand cases: 2 kV Between 24 V power terminals and cases: 500 V Between 24 V power terminals and ?eld device terminals: 2 kV |
Ambient Temperature and Humidity | 0 to 50 °C, 10 to 90 %RH | 0 to 50 °C, 10 to 90 %RH | 0 to 50 °C, 10 to 90 %RH |
Standards | Safety Standard [CSA] (*3)EMC standards [CE Marking], [C-Tick Marking], [KC Marking] | Safety Standard [CSA] (*3)EMC standards [CE Marking], [C-Tick Marking], [KC Marking] | EMC standards [CE Marking], [C-Tick Marking], [KC Marking](*4) |
Size | W: 482.6 mm x H: 132.5 mm (3U) | W: 482.6 mm x H: 177 mm (4U) | W: 482.6 mm x H: 132.5 mm (3U) |
Weight | 2.2 kg | 2.6 kg | 2.2 kg |