国产睡熟迷奷系列网站,欧美激情一级精品国产,欧美高清在线观看一区二区,欧美黄片一区二区视频


免費(fèi)注冊(cè)快速求購


分享
舉報(bào) 評(píng)價(jià)

(四合一)痛覺測痛系統(tǒng)

參考價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)

該廠商其他產(chǎn)品

我也要出現(xiàn)在這里

四合一

詳細(xì)信息 在線詢價(jià)

詳細(xì)介紹

四合一痛覺測試系統(tǒng)包含電子von Frey測痛儀、鼠爪壓力測量儀、鼠爪腫脹測量儀、抓力測量儀四套電子痛覺測量儀用四種方法完成對(duì)大鼠小鼠等動(dòng)物的痛覺。


  • Electronic von Frey Anesthesiometer 電子von Frey測痛儀

  • Randall Selitto test Paw Pressure Test Meter 鼠爪壓力測量儀

  • Plethysmometer, Paw Volume Meter or Paw Edema Meter鼠爪腫脹測量儀

  • Grip Strength Meter Mice and Rats 抓力測量儀


型號(hào)2390型+2500型+520MR型+2200型


電子觸覺閾疼痛閾測量儀機(jī)械痛閾測量儀Von Frey系統(tǒng)簡單易用。用來替代傳統(tǒng)的Von Frey Hairs纖毛機(jī)械刺激針Von Frey Hairs.不僅可以Von Frey test測試機(jī)械痛閾或觸覺閾測量還可以測試疼痛閾值。它使研究者可以自動(dòng)記錄機(jī)械痛閾和觸覺閾測量。操作簡單精確設(shè)計(jì)緊湊。


電子Von Frey測痛儀的主要特點(diǎn)

適用MRI探針

單體內(nèi)可插入三個(gè)探針

LCD 顯示屏 (Floating or last max. & minimum) 

硬槍頭能達(dá) 800 Gr. 

“Supertips™” 15 65Gr. 

適用1K探針

電子微處理器0.1Gr插入式探針

可選的模擬輸出線

吸頭可根據(jù)情況定制

具有測量、存儲(chǔ)和顯示功能免除了手算的繁瑣。

可以預(yù)設(shè)和選擇大限額能精確到1g當(dāng)?shù)筋A(yù)設(shè)的限額時(shí)警示燈會(huì)通知使用人員。

實(shí)驗(yàn)簡便選擇合適的原件放在探針上插進(jìn)實(shí)驗(yàn)對(duì)象根據(jù)實(shí)驗(yàn)對(duì)象的反應(yīng)儀器就能快速的顯示出結(jié)果并儲(chǔ)存。

作為核心原件的內(nèi)置傳感器固定在元件上并和電子系統(tǒng)相連以便記錄數(shù)據(jù)。所有的電子測痛儀已在出廠前校準(zhǔn)完畢不再需要購買任何的校準(zhǔn)設(shè)備。


鼠爪壓力測痛儀 Randall&Selitto測試通過逐步提高作用于動(dòng)物爪子上的機(jī)械壓力逼近動(dòng)物的疼痛閾限測量并記錄動(dòng)物產(chǎn)生逃避反應(yīng)時(shí)的瞬間大壓力以測定動(dòng)物機(jī)械鈍痛的痛覺閾限。


與熱痛不同鼠爪壓力疼痛測痛用于機(jī)械壓痛和鈍痛的痛覺測量常用于辨別左右爪不同的痛覺反應(yīng)多涉及脊髓神經(jīng)過程人工辨別動(dòng)物縮腿反應(yīng)并用踏板控制馬達(dá)的起止。


鼠爪壓力疼痛測試儀的主要特點(diǎn) 

適用于大鼠和小鼠

精確度為0.1克大壓力400

數(shù)字顯示功能

配置腳踏控制器

RS-232輸出


爪體積測量儀用來衡量消炎藥的有效性。使用時(shí)講大鼠、小鼠的爪子浸入含有特殊細(xì)胞的水中由于浸泡水的壓力發(fā)生了變化。壓力的變化會(huì)被校準(zhǔn)并顯示在特殊的電子監(jiān)視器上。這種檢測形式可以消除由于重復(fù)浸入發(fā)生導(dǎo)電性的改變而產(chǎn)生的改變這種情況在類似的其他儀器上發(fā)現(xiàn)過。測試結(jié)果直接顯示在LCD上(大鼠精確到0.01毫升、小鼠精確到0.001毫升)。無論是用電池還是用9V12V的適配器該設(shè)備表現(xiàn)穩(wěn)定操作安全

 

鼠爪腫脹測定儀的主要特點(diǎn) 

無需潤濕液可消除由于重復(fù)浸入發(fā)生導(dǎo)電性的改變而產(chǎn)生的體積誤差 

配備90°角的全透明亞克力操作支架可進(jìn)行清晰方便

維護(hù)方便不需要特殊的護(hù)理液

數(shù)據(jù)準(zhǔn)確不需要每次使用校準(zhǔn)每年僅需校正一次

具有內(nèi)置電源實(shí)現(xiàn)停電不間斷操作

帶LCD顯示器讀書方便

體積精確度0.01ml(大鼠)0.001ml(小鼠)


鼠抓力測量儀可用于小鼠或大鼠系統(tǒng)測試的使大鼠或小鼠釋放的抓力。常用于藥物、毒物、肌肉松弛藥、衰老、神經(jīng)損傷對(duì)肌力的影響。將大鼠或小鼠置于有機(jī)玻璃平臺(tái)上在抓力吊架前面。嚙齒動(dòng)物會(huì)本能地抓取任何東西以嘗試去停止這種被動(dòng)的反向運(yùn)動(dòng)這將會(huì)持續(xù)抓吊臺(tái)直到牽力克服了抓力為止。動(dòng)物失去其抓力后力峰值前級(jí)放大器會(huì)自動(dòng)地儲(chǔ)存峰值的抓力并顯示在液晶板上。


大小鼠抓力測量儀的主要特點(diǎn)

拉力傳感器大力度值≥1500g 

大力可允許超過數(shù)值≥150g

讀數(shù)精度為0.1g

配備有基座、金屬套桿和傳感器Hub

配大小鼠網(wǎng)格和T形桿

陽極電鍍處理的面板并配備有固定吸盤

配備36g砝碼校準(zhǔn)模塊

數(shù)據(jù)采集器自帶電源可供數(shù)據(jù)采集器時(shí)間≥250小時(shí)

帶Clear清零鍵使用方便


Our newest addition to our Analgesia line can perform the Electronic von Frey, Digital Randall Selitto, Plethysmometer and Grip Strength Meter test with one electronic system.

Order any one of the test systems complete and the only additional item(s) needed are the individual modules to perform each test.

Electronics has up to three inputs allowing users to perform four very different tests with one electronic system when studies call for doing so.

All data is stored and displayed in the electronics supplied.


Part# 2650 Stand and sling sold separay





Example: 
Order any one of the 2390 Series Electronic von Frey systems; add on either or both the Digital Paw Pressure Applicator only and/or the glass stand setup only and you have a system that is complete for all three individual tests.

A wonderful addition to any laboratory facility studying analgesic compounds in research.

Stand and animal sling for Randall Selitto test sold separay.


部分參考文獻(xiàn)

 

[HTML] An electronic pressure-meter nociception paw test for mice

TM CunhaWA Verri Jr, GG Vivancos… - Brazilian Journal of , 2004 - SciELO Brasil

... an inflammatory process and sensitized the paws of mice with different doses of carrageenin
and prostaglandin E 2 (PGE 2 ... consisted of a hand-held force transducer fitted with a 0.5 mm
2 polypropylene tip (electronic von Frey anesthesiometer, IITC Inc., Life ...

 

[HTML] Pharmacological characterisation of a rat model of incisional pain

GT Whiteside, J Harrison, J Boulet… - British journal of , 2004 - Wiley Online Library

... Pharma, Neuropharmacology, 6 Cedar Brook Drive, Cranbury, NJ 08512, USA E-mailgarth ... Issue
published online2 FEB 2009; Article first published online2 FEB 2009; ... previously described
in this modeltactile allodynia using an automated electronic von Frey (IITC, CA, USA ...

 

Pharmacological characterization of the chronic constriction injury model of neuropathic pain

J De Vry, Kuhl, P Franken-Kunkel, G Eckel - European journal of , 2004 - Elsevier

... 4 December 2003 Revised 1 March 2004 Accepted 25 March 2004 Available online 10 May
2004. Abstract. ... Mechanical allodynia was measured by means of a pressure transducer (electronic
von Frey Anaesthesiometer, IITC-Life Science Instruments, Woodland Hills, CA). ...

 

Selective activation of cannabinoid CB2 receptors suppresses neuropathic nociception induced by treatment with the chemotherapeutic agent paclitaxel in rats

EJ Rahn, AM Zvonok, GA Thakur, AD Khanolkar… … of Pharmacology and , 2008 - ASPET

... E-mailahohmann{at}uga.edu. Next Section. Abstract. ... Mechanical withdrawal thresholds were
assessed using a digital electronic von Frey anesthesiometer (IITC model Alemo 2290-4; IITC
Life Sciences Inc., Woodland Hills, CA) equipped with a rigid tip. ...

 

Pharmacological and pharmacokinetic characterization of the cannabinoid receptor 2 agonist, GW405833, utilizing rodent models of acute and chronic pain, anxiety, 

KJ Valenzano, L Tafesse, G Lee, JE Harrison… , 2005 - Elsevier

... 2004 Revised 26 November 2004 Accepted 10 December 2004 Available online 19 February ...
The marble-burying behavior model of anxiety (Njung'e and Handley, 1990 ... noxious tactile stimulus
(VWT) were determined using an automated electronic von Frey apparatus (IITC ...

 

Taurine replacement attenuates hyperalgesia and abnormal calcium signaling in sensory neurons of STZ-D rats

F Li, IG Obrosova, O Abatan, D Tian… - American Journal of , 2005 - Am Physiological Soc

... Digital sensory NCV (SNCV) was recorded in the digital nerve to the second toe by stimulating
with a square ... by quantifying the withdrawal threshold of the hindpaw in response to mechanical
stimulation using a von Frey anesthesiometer (model 2290C; IITC Life Science ...

 

Activation of presynaptic NMDA receptors coupled to NaV1. 8-resistant sodium channel C-fibers causes retrograde mechanical nociceptor sensitization

CA Parada, GG Vivancos, CH Tambeli… - Proceedings of the , 2003 - National Acad Sciences

... Intrathecal administration of prostaglandin E 2 (PGE 2 ), glutamate, and NMDA causes a bilateral
long-lasting mechanical paw hypernociception ... reflex with a hand-held force transducer adapted
with a 0.5-mm 2 polypropylene tip (electronic von Frey hair; IITC Life Science ...

 

The use of an electronic von Frey device for evaluation of sensory threshold in neurologically normal dogs and those with acute spinal cord injury

SA Moore, BF Hettlich, A Waln - The Veterinary Journal, 2013 - Elsevier

... Accepted 3 November 2012 Available online 13 December 2012. Abstract. The ...
examination. von Frey device. The electronic von Frey device (IITC Life Science)
consisted of a load cell, handle, recording device and tip (Fig. 1 ...



    

    

    

         

    

    

    

    

 


同類產(chǎn)品推薦


提示

×

*您想獲取產(chǎn)品的資料:

以上可多選,勾選其他,可自行輸入要求

個(gè)人信息:

国产精品亚洲一区二区三区欲| 精品无码中文字幕在线| 欧美大片免费看片入口| 日韩欧美精品在线中文字幕| 欧美亚洲综合中文字幕蜜桃成熟| 欧美综合亚洲日韩精品区| 欧美精品97在线观看| 日韩码一码二码三码区别| 日韩精品一区二区三区视频最新| 在线电影日韩一区二区三区| 国产亚洲一区二区三区午夜| 亚洲av成人精品日韩一区麻豆| 国内精品国产三级国产av万事达| 有码无码人妻一区二区| 欧美日本一道本一区二区三区| 久久亚洲国产精品五月天| 国产亚洲视频中文字幕97精品| 人碰人碰人人97免费搜播| 亚洲影视一区二区三区| 日本一区二区三区综合| 丰满的大乳老师三级在线观看| 中文字幕日本一区二区在线观看| 久久蜜臀亚洲一区二区| 日韩免费码中文字幕在线| 国产一二三区亚洲欧美| 国产欧美在线观看精品一区污| 美女草草影院在线观看视频| 93国产精品久久久久久| 人妻熟女的高跟丝袜艳遇| 一区二区三区四区欧美日韩亚洲| 亚洲欧美成人激情在线| 有码无码人妻一区二区| 国产69精品久久久久久老妇| 不卡在线视频一区二区| 日韩一二三区中文字幕在线视频精品| 一区二区久久久久久久久| 日本一区二区三区中文字幕八戒视频| 一区二区久久久久久久久| 97精品国产综合久久久免费| 色欲香天天综合免费区一区二| 中文字幕日韩欧美推理片免费观看|